'''Modal testing''' is |
'''Modal testing''' is the form of [[vibration|vibration testing ]] of an object whereby the natural (modal) frequencies, modal masses, modal damping ratios and mode shapes of the object under test are determined. |
||
A modal test |
A modal test consists of an acquisition phase and an analysis phase. The complete process is often referred to as a [[Modal Analysis]] or Experimental Modal Analysis. |
||
⚫ | There are several ways to do modal testing |
||
[[Image:M1w1Layout.jpg|frame|center|alt=Layout of a modal testing system|Sample layout of a modal testing system]] |
|||
⚫ | There are several ways to do modal testing but impact hammer testing and shaker (vibration tester) testing are commonplace. In both cases [[energy]] is supplied to the system with a known frequency content. Where structural resonances occur there will be an [[Amplifier|amplification]] of the response, clearly seen in the response spectra. Using the response spectra and force spectra, a [[transfer function]] can be obtained. The transfer function (or [[frequency response function]] (FRF)) is often [[curve fitting|curve fitted]] to estimate the modal parameters; however, there are many methods of modal [[Estimation theory|parameter estimation]] and it is the topic of much research.[[File:Vibration testing.svg|thumb|Key components for performing experimental modal analysis.|center|636x636px]] |
||
== Impact Hammer Modal Testing == |
== Impact Hammer Modal Testing == |
||
[[File:Modal hammer.jpg|thumb|Modal impact hammer with interchangeable tips and accompanying temporal and frequency responses]] |
|||
⚫ | An ideal impact to a structure is a perfect impulse, which has an infinitely small duration, causing a constant amplitude in the frequency domain; this would result in all modes of vibration being excited with equal energy. The impact hammer test is designed to replicate this; however, in reality a hammer strike cannot last for an infinitely small duration, but has a known contact time. The duration of the contact time directly influences the frequency content of the [[force]], with a larger contact time causing a smaller range of bandwidth. A load cell is attached to the end of the hammer to |
||
⚫ | An ideal impact to a structure is a perfect impulse, which has an infinitely small duration, causing a constant amplitude in the frequency domain; this would result in all [[modes of vibration]] being excited with equal energy. The impact hammer test is designed to replicate this; however, in reality a hammer strike cannot last for an infinitely small duration, but has a known contact time. The duration of the contact time directly influences the frequency content of the [[force]], with a larger contact time causing a smaller range of bandwidth. A [[load cell]] is attached to the end of the hammer to record the force. Impact hammer testing is ideal for small lightweight structures. However, as the size of the structure increases, issues can occur due to a poor [[signal-to-noise ratio]], which is common on large [[civil engineering]] structures. |
||
== Shaker Modal Testing == |
== Shaker Modal Testing == |
||
A shaker is a device that excites the structure according to its amplified input signal. Several input signals are available for modal testing, but the sine sweep |
A shaker is a device that excites the object or structure according to its amplified input signal. Several input signals are available for modal testing, but the sine sweep and random frequency vibration profiles are by far the most commonly used signals. |
||
Small objects or structures can be attached directly to the [[Simulation table|shaker table]]. With some types of shakers, an armature is often attached to the body to be tested by way of piano wire (pulling force) or stinger (pushing force). When the signal is transmitted through the piano wire or the stinger, the object responds the same way as impact testing, by attenuating some and amplifying certain frequencies. These frequencies are measured as modal frequencies. Usually a load cell is placed between the shaker and the structure to obtain the excitation force. |
|||
For large civil engineering structures much larger shakers are used, which can |
For large civil engineering structures much larger shakers are used, which can have a mass of 100 [[kg]] and above, and are able to apply a force of many hundreds of [[newtons]]. Several types of shakers are common: rotating mass shakers, electrodynamic shakers, and electrohydraulic shakers. For rotating mass shakers, the force can be calculated by knowing the mass and the speed of rotation, while for electrodynamic shakers, the force can be obtained through a load cell or an accelerometer placed on the moving mass of the shaker. Shakers have an advantage over the impact hammer as they can supply more energy to a structure over a longer period of time. However, problems can also be introduced; shakers can influence the dynamic properties of the structure and can also increase the complexity of analysis due to [[window function|windowing]] errors. |
||
== |
==See also== |
||
*[[Modal Analysis]] |
|||
*[http://www.pcb.com/techsupport/tech_hammers.php Impact Hammer Selection Guide] |
|||
*[[Vibration]] |
|||
*[[Cushioning]] |
|||
*[[Shock absorber]] |
|||
*[[Shock (mechanics)]] |
|||
*[[Shock response spectrum]] |
|||
*[[Shaker (testing device)]] |
|||
==References== |
|||
{{Reflist}} |
|||
[[Category:Wave mechanics]] |
[[Category:Wave mechanics]] |
||
[[Category:Tests]] |
|||
[[de:Modalanalyse]] |
[[de:Modalanalyse]] |
Latest revision as of 14:30, 10 June 2024
Modal testing is the form of vibration testing of an object whereby the natural (modal) frequencies, modal masses, modal damping ratios and mode shapes of the object under test are determined.
A modal test consists of an acquisition phase and an analysis phase. The complete process is often referred to as a Modal Analysis or Experimental Modal Analysis.
There are several ways to do modal testing but impact hammer testing and shaker (vibration tester) testing are commonplace. In both cases energy is supplied to the system with a known frequency content. Where structural resonances occur there will be an amplification of the response, clearly seen in the response spectra. Using the response spectra and force spectra, a transfer function can be obtained. The transfer function (or frequency response function (FRF)) is often curve fitted to estimate the modal parameters; however, there are many methods of modal parameter estimation and it is the topic of much research.
Impact Hammer Modal Testing
[edit]An ideal impact to a structure is a perfect impulse, which has an infinitely small duration, causing a constant amplitude in the frequency domain; this would result in all modes of vibration being excited with equal energy. The impact hammer test is designed to replicate this; however, in reality a hammer strike cannot last for an infinitely small duration, but has a known contact time. The duration of the contact time directly influences the frequency content of the force, with a larger contact time causing a smaller range of bandwidth. A load cell is attached to the end of the hammer to record the force. Impact hammer testing is ideal for small lightweight structures. However, as the size of the structure increases, issues can occur due to a poor signal-to-noise ratio, which is common on large civil engineering structures.
Shaker Modal Testing
[edit]A shaker is a device that excites the object or structure according to its amplified input signal. Several input signals are available for modal testing, but the sine sweep and random frequency vibration profiles are by far the most commonly used signals.
Small objects or structures can be attached directly to the shaker table. With some types of shakers, an armature is often attached to the body to be tested by way of piano wire (pulling force) or stinger (pushing force). When the signal is transmitted through the piano wire or the stinger, the object responds the same way as impact testing, by attenuating some and amplifying certain frequencies. These frequencies are measured as modal frequencies. Usually a load cell is placed between the shaker and the structure to obtain the excitation force.
For large civil engineering structures much larger shakers are used, which can have a mass of 100 kg and above, and are able to apply a force of many hundreds of newtons. Several types of shakers are common: rotating mass shakers, electrodynamic shakers, and electrohydraulic shakers. For rotating mass shakers, the force can be calculated by knowing the mass and the speed of rotation, while for electrodynamic shakers, the force can be obtained through a load cell or an accelerometer placed on the moving mass of the shaker. Shakers have an advantage over the impact hammer as they can supply more energy to a structure over a longer period of time. However, problems can also be introduced; shakers can influence the dynamic properties of the structure and can also increase the complexity of analysis due to windowing errors.
See also
[edit]- Modal Analysis
- Vibration
- Cushioning
- Shock absorber
- Shock (mechanics)
- Shock response spectrum
- Shaker (testing device)