[go: nahoru, domu]

Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Altherma 3 R ECH2O #350

Open
rob570 opened this issue Nov 19, 2023 · 12 comments
Open

Altherma 3 R ECH2O #350

rob570 opened this issue Nov 19, 2023 · 12 comments

Comments

@rob570
Copy link
rob570 commented Nov 19, 2023

Hi to everyone and Thank you Raomin for your project.
I've configured ESPAltherma for an Altherma 3 R ECH2O. I've used Top-Grade.h with two fixes.
I'm not able to find the registry for querying:

  1. mixed temperature (R7T) the one found in other definitions don't work (always 0): {0x64,10,105,2,1,"Mixed water temp."},{0x64,10,118,2,1,"Mixed water temp.(R7T)"} -- Sorry I've seen many requests in discussion. Unluckly still no answer.
  2. Tank Valve (M1S)
  3. Bypass Valve (M2S)

Here what I fixed in the description:

  • {0x20,0,105,2,1,"Outdoor air temp.(R1T)"} should be {0x20,0,105,2,1,"Outdoor air temp.(R6T)"}
  • {0x64,7,105,2,1,"Boiler Heating Target Temp."} it is the SH Water Heating Temp

Could anyone help me?
Thank you,
Roberto
immagine

@maromme
Copy link
maromme commented Nov 20, 2023

I found those somewhere here in the discussions:

{0x63,8,105,2,1,"[HPSU] Mixed leaving water temperature after the tank R7T (DLWA2)"},
{0x63,10,101,1,-1,"[HPSU] Tank valve position (0:Bypass 100:Tank)"},
{0x63,11,101,1,-1,"[HPSU] Bypass valve position (0:Bypass 100:Emitter)"},
{0x20,0,105,2,1,"R6T"},

@lfrancke
Copy link

Maybe these are helpful for you as well: ech2o.csv

@rob570
Copy link
Author
rob570 commented Nov 21, 2023

Dear Maromme and Ifrancke,
thank you for helping and sharing.
I'll try next week and I'll give you a feedback.
Have a nice day,
Roberto

@rob570
Copy link
Author
rob570 commented Nov 26, 2023

Hi, I can confirm the settings provided work!
Thank you for your reply.
I attach a new definition file (renamed to csv) based on your information.
ALTHERMA(ECH2O).h.csv
Roberto

@simonebortolin
Copy link

@lfrancke @rob570 why
{0x62,11,405,1,1,"Water pressure"},
and not
{0x62,11,105,1,1,"Water pressure"},

the conversion 405 is only for the R32 gas inside the refrigerant circuit.

@rob570
Copy link
Author
rob570 commented Jan 1, 2024

Thank you Simone,
That's why even after pulling the breaks on 405 conv ( #325 ) I've got wrong values.
Grazie!

@simonebortolin
Copy link

how many Italians with this heat pump!

@simonebortolin
Copy link
simonebortolin commented Jan 1, 2024

I am only missing the two 3-way valve values...

Only Refrig. Temp. liquid side (R3T) is Wrong

image
IMG_20240101_114711

@danilo-quadrelli
Copy link

Hi, I can't confirm the settings provided work!
In my case:
{0x62,11,405,1,1,"Pressione acqua"}, return
Pressione acqua: -51.1813 (Daikin 1,3 Bar)

{0x62,11,105,1,1,"Pressione acqua"}, return
Pressione acqua: 0 (Daikin 1,3 bar)

and:

{0x63,10,101,1,-1,"[HPSU] Tank valve position (0:Bypass 100:Tank)"},
{0x63,11,101,1,-1,"[HPSU] Bypass valve position (0:Bypass 100:Emitter)"},

[HPSU] Tank valve position (0:Bypass 100:Tank): 0
[HPSU] Bypass valve position (0:Bypass 100:Emitter): 0 (Daikin 12%)

Thank you

@simonebortolin
Copy link
In my case:
{0x62,11,405,1,1,"Pressione acqua"}, return
Pressione acqua: -51.1813 (Daikin 1,3 Bar)

{0x62,11,105,1,1,"Pressione acqua"}, return
Pressione acqua: 0 (Daikin 1,3 bar)

Molto strano, a me torna il valore corretto

{0x63,10,101,1,-1,"[HPSU] Tank valve position (0:Bypass 100:Tank)"},
{0x63,11,101,1,-1,"[HPSU] Bypass valve position (0:Bypass 100:Emitter)"},

pure queste a me tornano corretti i valori, che modello di ECH2O hai?

@danilo-quadrelli
Copy link

Daikin Altherma 3 R ECH2O:

EHSXB08P30DA

@simonebortolin
Copy link
simonebortolin commented Jan 2, 2024

vecchia elettronica, potrebbe essere molto diverso da quelli dalla serie nuova con eye

c'è roba da prendere con il connettore CAM

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

5 participants