Hueso-González et al., 2016 - Google Patents
Prompt gamma rays detected with a BGO block Compton camera reveal range deviations of therapeutic proton beamsHueso-González et al., 2016
View PDF- Document ID
- 6091754091158201468
- Author
- Hueso-González F
- Pausch G
- Petzoldt J
- Römer K
- Enghardt W
- Publication year
- Publication venue
- IEEE Transactions on Radiation and Plasma Medical Sciences
External Links
Snippet
The dose deposition profile of protons is interesting for tumour treatment due to the increased ionization density at the end of their track. However, the inaccurate knowledge of the proton stopping point limits the precision of the therapy. Prompt gamma rays, a by …
- 230000001225 therapeutic 0 title description 2
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2018—Scintillation-photodiode combination
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/10—Luminescent dosimeters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/169—Exploration, location of contaminated surface areas in situ measurement, e.g. floor contamination monitor
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/167—Measuring radioactive content of objects, e.g. contamination
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/36—Measuring spectral distribution of X-rays or of nuclear radiation spectrometry
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T5/00—Recording of movements or tracks of particles; Processing or analysis of such tracks
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T7/00—Details of radiation-measuring instruments
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21K—TECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
- G21K1/00—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating
- G21K1/02—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating using diaphragms, collimators
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T3/00—Measuring neutron radiation
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Hueso-González et al. | Prompt gamma rays detected with a BGO block Compton camera reveal range deviations of therapeutic proton beams | |
Krimmer et al. | Prompt-gamma monitoring in hadrontherapy: A review | |
Pausch et al. | Detection systems for range monitoring in proton therapy: Needs and challenges | |
Richard et al. | Design guidelines for a double scattering compton camera for prompt-$\gamma $ imaging during ion beam therapy: a monte carlo simulation study | |
Hueso-González et al. | Compton camera and prompt gamma ray timing: two methods for in vivo range assessment in proton therapy | |
Solevi et al. | Performance of MACACO Compton telescope for ion-beam therapy monitoring: first test with proton beams | |
Smeets et al. | Prompt gamma imaging with a slit camera for real-time range control in proton therapy | |
EP2670485B1 (en) | An apparatus for particle therapy verification | |
Golnik et al. | Tests of a Compton imaging prototype in a monoenergetic 4.44 MeV photon field—a benchmark setup for prompt gamma-ray imaging devices | |
US20070040115A1 (en) | Method for calibrating particle beam energy | |
Krimmer et al. | Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations | |
JP6699004B2 (en) | Neutron capture therapy system and method of controlling neutron capture therapy system | |
Hueso-González et al. | Comparison of LSO and BGO block detectors for prompt gamma imaging in ion beam therapy | |
Richard et al. | Design study of the absorber detector of a Compton camera for on-line control in ion beam therapy | |
US10989676B2 (en) | Gamma-ray image acquisition device and gamma-ray image acquisition method | |
Lohrabian et al. | Comparison of the X-ray tube spectrum measurement using BGO, NaI, LYSO, and HPGe detectors in a preclinical mini-CT scanner: Monte Carlo simulation and practical experiment | |
Magalhaes Martins et al. | A single-particle trigger for time-of-flight measurements in prompt-gamma imaging | |
JP7555351B2 (en) | Charged particle radiotherapy verification system | |
Lopes et al. | Optimization of the signal-to-background ratio in prompt gamma imaging using energy and shifting time-of-flight discrimination: Experiments with a scanning parallel-slit collimator | |
Ferri et al. | A collimator study towards BNCT-SPECT systems for dose monitoring | |
Richard et al. | Design study of a Compton camera for prompt γ imaging during ion beam therapy | |
Honda et al. | Shape distortion of 128I ß− spectrum observed by a self-activated CsI (Tl) scintillator for high-sensitivity neutron measurements | |
Turko et al. | Characterization of organic glass scintillator bars and their potential for a hybrid neutron/gamma ray imaging system for proton radiotherapy range verification | |
Dauvergne et al. | New methods of real-time control imaging for ion therapy | |
Agosteo et al. | A telescope detection system for direct and high resolution spectrometry of intense neutron fields |